Electrical Requirements

70304601

38

Conversion Instructions

If serial plate voltage is:

Tumbler can be converted to the following voltages:

120 Volt/60 Hertz/
1 Phase

2W&G

(T30 Models Only)

208-240 Volt/60 Hertz/1 Phase Models:
3W&G

1. Prior to connecting service, locate the black/red wire which runs between

terminal block and the motor relay or contactor. Refer to figure below.

2. Disconnect the black/red lead from L1 of the terminal block and connect to

L2 of the terminal block. Repeat steps 1 and 2 for upper and lower junction
box areas.

3. Sign and date conversion sticker located on back of tumbler.

4. Follow the instructions covered in Connecting Electrical Service section.

240 Volt/60 Hertz/
3 Phase

3W&G

200-208 Volt/60 Hertz/3 Phase Models:
3W&G

1. Prior to connecting electric service, locate transformer configuration jumper

in junction box area.

2. Remove the 240 Volt jumper and replace it with the 208 Volt jumper located

in the literature packet in cylinder.

3. Repeat steps 1 and 2 for each upper and lower unit.

4. Sign and date conversion sticker located on back of tumbler.

5. Follow the instructions covered in Connecting Electrical Service section.