Exhaust Requirements

70304601

26

NOTE: Do not install wire mesh or screen in
exhaust duct opening to avoid lint build-up or
impacting proper discharge of air from tumblers.

NOTE: Where exhaust duct pierces a combustible
wall or ceiling, the opening must be sized per local
codes.

NOTE: Inside of duct must be smooth. Do not use
sheet metal screws to join sections.

Consult your local building code for regulations which
may also apply.

TMB2103N

1

Removable strip of panel in framing wall to permit removal of tumbler from framing wall

2

Partition or bulkhead

3

Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm)

4

2 in. (51 mm) minimum clearance on both sides of duct

5

Exhaust airflow – maximum length of duct: 14 ft. (4.3 m)

Figure 9