Communications wiring – Electro Cam PS-6144 Series User Manual

Page 23

Advertising
background image

2-15 Installation & Wiring

Communications Wiring

DB-9F Port

Serial communication to a PLC or other system host is provided through a DB-9 female
connector as shown in Figures 5 & 6. This connector can be wired for RS-232 or RS-
485 communications.

RS-485

RS-485 can be used for “multi-drop” networks where more than one controller could be
connected to the system host.

RS-232

RS-232 can connect only a single PS-6144 to a system host.

RS-232/485 Selection

Use the COMMUNICATIONS function to select RS-232 or RS-485 communications.

Figure 15—Communications Wiring

DB-9 Female Connector on Controller

(See Figures 5 & 6 for Location)

RS-232 Cable Wiring

DB-25 (Host) to DB-9F (PS-6144)*

RS-232 Cable Wiring

DB-9 (Host) to DB-9F (PS-6144)*

*Pins 1, 4, 6, 7 and 8 must NOT be connected.
Damage may result from using an off-the-shelf
RS-232 communications cable.

Be sure to follow illustrations, as they are NOT
STANDARD configurations!