Output enable anding, Output groups, 18 programming – Electro Cam PS-6144 Series User Manual

Page 46: Continued)

Advertising
background image

3-18 Programming

Output Enable ANDing

Menu Path

MAIN SCREEN

to CONFIG MENU

to CHN ANDING MENU

to

OUTPUT ENABLE ANDING

Purpose

Output Enable ANDing allows you to AND any output channels with Input Terminal
#16, Figure 7. A channel ANDed with this terminal will be enabled to turn on at its
programmed setpoints only while the terminal is energized.

Screen

CHN: 12<
OUTPUT AND: OFF

Channel number
Output Enable ANDing: ON or OFF.
(Toggle with SEL key)

Programming

Select a new channel by pressing INC/DEC, or using the numeric keys followed by
ENT.

Use the SEL key to toggle ANDing on and off.

Output Groups

M

enu Path

MAIN SCREEN

to CONFIG MENU

to OUTPUT GROUPS

Purpose

This function allows you to divide output channels into groups, and assign operating
modes to the groups. Operating modes provide a powerful tool for relating output chan-
nel operation to sensor signals or other inputs. Incorporating modes into a control sys-
tem can greatly improve line efficiency, reduce scrap, and improve control accuracy
between machine sections at high speeds. See Section 5 for a complete explanation of
the uses and applications of operating modes.

Screen

Establishing Groups

When dividing outputs into groups, keep these rules in mind:

• Output channels are assigned to groups sequentially. Group 1 will begin with Output

1 and include the specified number of outputs; Group 2 will begin with the next output
and continue sequentially for its specified number of outputs; and so on. The last
group will automatically include all of the remaining outputs.

• You can establish as many as six groups or as few as one.

• More than one group can be assigned to the same mode.

Grouping Example 1—All Outputs in One Group

Output

Includes

Group

Outputs

Mode

1

1 thru 25

3

Grouping Example 2—Two Groups

Output

Includes

Group

Outputs

Mode

1

1 thru 4

2

2

5 thru 25

0

(continued)

GRP:1 <GRP QTY:2
CHNS: 15 MODE: 3

Number of output groups
Enable mode of selected group

Number of channels in selected group

Selected group number