3-8 Programming

Enable Codes

Menu Path

MAIN SCREEN

to CONFIG MENU

to PGM ENABLE MENU

ENABLE CODES

Background

The PS-6144 has three levels of programming access: Operator, Setup, and Master in
order of increasing capabilities. Figure 21 lists the menu functions that can be pro-
grammed under the various levels of access.

Programming levels can be activated, or “enabled,” by entering a password on the
keypad, or by activating Terminals E1 or E2 on the back of the keypad as shown in
Figure 12. The first two rows of Figure 21 show which methods can be used to enable
the various levels of programming access.

Screen

LEVEL: OPERATOR
PASSWORD: 1234

Enable Level: Operator, Setup, or Master
Password Number

This screen is used to establish the numbers that will be used as passwords to enable
the Operator, Setup, and Master levels.

Use the SEL key to toggle between enable levels.

Use the numeric keys, followed by ENT to assign codes.

Operation

• Each programming level can have only one code. That code is stored in the controller

and applies to all keypads connected to that controller.

• If a code is entered into a keypad that has a programming enable terminal energized,

the access level will be the highest of the two.

• If one keypad in a two-keypad system is enabled, the other keypad will continue to

operate in the “Normal Display” mode.

• If both keypads in a two-keypad system are enabled, each keypad will operate at the

programming level enabled on it. For example, if Operator Level is enabled on Key-
pad 1, and Setup Level is enabled on Keypad 2, Keypad 1 will operate at the Opera-
tor Level and Keypad 2 will operate at the Setup Level.