3-10 Programming

Group Position Display

Menu Path

MAIN SCREEN

to CONFIG MENU

DISPLAY MENU

to GRP POS DISP

Purpose

The Group Position Display determines whether each output group can have its own
position in the machine cycle, or if all groups share one position. Because the position
of a group operating in Mode 1 or 2 changes each time the group’s input terminal is
energized, GRP POS DISP must be set to EACH if any groups are assigned to
Mode 1 or Mode 2.

Screen

Enable Options

Menu Path

MAIN SCREEN

to CONFIG MENU

to PGM ENABLE MENU

to ENABLE OPTIONS

Purpose

The Enable Options screen controls Operator Level access to SETUP MENU program-
ming as indicated in Figure 21, note 1.

Screen

SETPOINTS<
ENABLE: ON

SETPOINTS or SETUP MENU screen.
Scroll through choices with UP and Down cursor keys.

OPERATOR ENABLE: ON/OFF
(Toggle with SEL key)

This screen lists the various items in the SETUP MENU, and allows you to turn Opera-
tor access to those items on or off.

Access to the “on” items will be available only for those output channels that
have been turned ON in PER CHN ENABLE.

Programming

Press the Up Cursor and Down Cursor keys to select the function you wish to change.
Press the SEL key to turn Operator access ON or OFF.

Setup Menu Items

Access can be turned on or off for the following SETUP MENU items:

SETPOINTS, DEFAULT PROGRAM
SPEED COMP
OFFSET
MOTION DETECT
ANALOG OUTPUTS

See Also

PER CHN ENABLE

GROUP POSITION
DISPLAY: EACH<

Group Position Display Mode: EACH = Each ouput
group has its own offset value; ONE = One value
of offset is shared by all output groups.