3-24 Programming

Rate Setup

Menu Path

MAIN SCREEN

to CONFIG MENU

to DISPLAY

RATE SETUP

Purpose

The Rate Setup function allows you to configure the RPM display on the Main Screen.
Three parameters can be programmed:

Units—The Main Screen can label the resolver speed as Revolutions Per Minute

(RPM), Bags Per Minute (BPM), Cartons Per Minute (CPM), or Inches Per Minute
(IPM).

• Rate—The ratio of actual resolver RPM to displayed RPM. This ratio is a fraction

consisting of a multiplier (MPY) over a divider (DIV).

• Decimal Points—The controller divides the Rate by 1, 10, 100, or 1000 to display 0,

1, 2, or 3 decimal places, respectively.

Screen

Following are a few examples of the relationships between multiplier (MPY), divider
(DIV), decimal points (DP), actual resolver speed, and displayed resolver speed:

If

And

And

Then

And a

Is

MPY

DIV

DP

MPY/DIV

Resolver

Displayed

Is…

Is…

Is…

Is…

Speed Of…

As…

1

2

0

.5

100 RPM

50 RPM

1

2

1

.5

100 RPM

5.0 RPM

1

2

2

.5

100 RPM

.50 RPM

1

2

3

.5

100 RPM

.050 RPM

1

1

0

1.0

100 RPM

100 RPM

1

1

1

1.0

100 RPM

10.0 RPM

1

1

2

1.0

100 RPM

1.00 RPM

1

1

3

1.0

100 RPM

.100 RPM

2

1

0

2.0

100 RPM

200 RPM

2

1

1

2.0

100 RPM

20.0 RPM

2

1

2

2.0

100 RPM

2.00 RPM

2

1

3

2.0

100 RPM

.200 RPM

Programming

Units—Move the cursor to the “Units” field and use SEL to toggle between values.

MPY & DIV—Move the cursor to MPY or DIV and use the numeric keys followed by
ENT to enter a value.

DP—Move the cursor to DP and use SEL to toggle between values.

MPY: 1< DP: 0
DIV: 1 RPM

Units: RPM, BPM, CPM, IPM

Divider: 1 through 63

Number of decimal points displayed: 0, 1, 2, or 3

Multiplier: 0 through 1091