3-15 Programming

Motion ANDing (Cont’d)

Programming

Select a new channel by pressing the INC/DEC keys, or through direct numeric entry
followed by ENT.

Press the SEL key to toggle the ANDing to L1, L2, or OFF.

Operation

• Any number of output channels can be ANDed to a single Motion Detection level.

• Motion ANDing and Output Enable ANDing can be combined for any given output

channel.

• When Motion ANDing is activated for a channel, it will apply to that channel in all

programs.

Motion Detector

An output channel can be used as a motion detector by programming it to be on at “1”
and off at “1,” and then ANDing it with the desired Motion Level. This will turn the output
on constantly as long as the machine speed is within the specified Motion Level range.

See Also

MOTION DETECTION

Motion Detection

Menu Path

MAIN SCREEN

to SETUP MENU

to MOTION DETECT

Background

Motion Detection establishes one or two “Motion Levels,” or speed ranges, with low and
high RPM values. These two ranges are independent of each other.

Each output channel can be ANDed with either Motion Level. ANDed outputs will be
enabled only when the resolver speed is within the specified speed range. Output chan-
nels that are not ANDed will be “on” whenever the machine position is within their
programmed setpoints, regardless of machine speed. One use of Motion Levels and
Motion ANDing is to turn off devices such as glue guns if the machine stops or jams.

The MOTION DETECTION function is used to establish one or two Motion levels. Once
the Motion Levels are programmed, use MOTION ANDING to tie individual output chan-
nels to the Motion Levels.

Screen

The Motion Detection screen displays the Motion Level, the Low RPM, and the High
RPM.

Programming

Use the numeric keys and ENT to change values for Motion Level, Low RPM, and High
RPM.

Motion Detector

An output channel can be used as a motion detector by programming it to be on at “1”
and off at “1,” and then ANDing it with the desired Motion Level. This will turn the output
on constantly as long as the machine speed is within the specified Motion Level range.

See Also

MOTION ANDING

MOTION LEVEL: 1
LO: 30 HI: 1500

Motion detection level
High RPM setpoint

Low RPM setpoint