3-22 Programming

Pulse Copy

M

enu Path

MAIN SCREEN

to SETUP MENU

to PULSE COPY

Purpose

Pulse Copy allows you to program a series, or “train” of pulses into a channel without
having to enter the On and Off setpoints for each pulse. The Pulse Copy function prompts
you for the beginning and ending setpoints for the pulse train; the number of pulses in
the train; and the duration of a pulse. Pulse Copy then divides the designated portion of
the resolver cycle into the specified number of pulses, evenly dividing the unused por-
tion of the segment between the pulses.

Screens

The Pulse Copy function consists of eight screens:

(continued)

PROGRAM:---<

Program to add pulses to;
Enter number, then SEL to go to next screen

CHANNEL:---<

Channel to add pulses to;
Enter number, then SEL to go to next screen

ON:---<

"On" time of leading edge of first pulse;
Enter number, then ENT & SEL to go to next screen

OFF:---<

"Off" time of trailing edge of last pulse;
Enter number, then ENT & SEL to go to next screen

COUNT---<

Total number of pulses to be added;
Enter number, then ENT & SEL to go to next screen

DURATION:---<

Duration of each pulse added;
Enter number, then ENT & SEL to go to next screen

DURATION: 35

EXECUTE<

Move cursor to EXECUTE, then press SEL to
generate pulses. To review values before executing,
move cursor to top row and press SEL as needed

DURATION: 35

COMPLETE<

COMPLETE indicates pulses have been generated

Program Select Mode

Menu Path

MAIN SCREEN

to CONFIG MENU

HARDWARE

to PGM SEL MODE

Purpose

This screen allows you to specify the format for the hardware Program Select inputs on
Terminals 1 through 8 of Terminal Block 3, Figure 7.

Screen

The Program Select inputs can operate in Binary, BCD, or Gray Code formats as shown
in Figure 8.

Use the SEL key to toggle the input format.

Injury and property damage hazard may occur due to changes in machinery op-
eration. If the input signals controlling program selection are lost due to a mal-
function, the Default Program will activate. Program the Default Program with
settings that will eliminate this hazard in the event of sudden activation.

See Also

DEFAULT PROGRAM

PROGRAM SELECT
MODE: BIN<

Hardware Program Select Format: BIN = Binary,
GRAY = Gray Code, BCD = Binary Coded Decimal

Advertising