Resolver type, Rpm udate rate, Scale factor – Electro Cam PS-6144 Series User Manual

Page 53: Rpm update rate, 25 programming

Advertising
background image

3-25 Programming

Resolver Type

Menu Path

MAIN SCREEN

to CONFIG MENU

to HARDWARE MENU

RESOLVER TYPE

Purpose

The PS-6144 can operate with resolvers that have a transformation ratio of .454 or 1.
Standard Electro Cam resolvers have a ratio of .454. Some resolvers made by other
manufacturers have a ratio of 1.

Screen

Scale Factor

Menu Path

MAIN SCREEN

to CONFIG MENU

to HARDWARE MENU

SCALE

FACTOR

Purpose

This function controls the number of increments into which one resolver revolution is
divided. A scale factor of 360 (0 to 359) allows the controller to operate in degrees. A
scale factor of 1024 (0 to 1023) allows positions to be programmed more accurately. In
some applications the scale factor can be set so each increment equals a unit of linear
travel.

Screen

Limits

Scale factors range from two to 1024 on standard controllers. For controllers equipped
with the “-H” option, scale factor can be as high as 4096.

Recalculations

When the scale factor is changed, all programmed setpoints are recalculated to convert
them to the new scale factor. The keypad/display will be inoperative until the calcula-
tions are done.

RPM Update Rate

Menu Path

MAIN SCREEN

to CONFIG MENU

to DISPLAY

RPM UPD RATE

Purpose

The RPM Update Rate is how often the RPM display on the Main Screen is updated.
This rate can be programmed to be 1/Sec, 2/Sec, or 10/Sec.

Screen

RPM UPDATE
RATE: 1/S<

RPM Update Rate: How often RPM display on main
screen is updated; 1/Sec, 2/Sec, or 10/Sec.

Press the SEL key to toggle the selection.

RESOLVER
TYPE: ECC<

Pressing the SEL key changes resolver type to OTHER.

SCALE
FACTOR: 360<

Number of increments each revolution is broken into