6-5 Communications

CMD
(hex)

Name

Function

56

Kbd Qty

Number of keypads connected.

Put:

! ADR 56 P XX CSM <CR>

Reply:

A <CR>

Get:

! ADR 56 G CSM <CR>

Reply:

A XX CSM <CR>

where “XX” = number of keypads connected.

0D

Setup ID

Setup ID code.

Put:

! ADR 0D P XXXX CSM <CR>

Reply:

A <CR>

Get:

! ADR 0D G CSM <CR>

Reply:

A XXXX CSM <CR>

where “XXXX” = Setup Enable Code in hex.

0E

Operator ID

Operator ID code.

Put:

! ADR 0E P XXXX CSM <CR>

Reply:

A <CR>

Get:

! ADR 0E G CSM <CR>

Reply:

A XXXX CSM <CR>

where “XXXX” = Operator Enable Code in hex.

58

Master ID

Master ID code.

Put:

! ADR 58 P XXXX CSM <CR>

Reply:

A <CR>

Get:

! ADR 58 G CSM <CR>

Reply:

A XXXX CSM <CR>

where “XXXX” = Master Enable Code in hex.

0F

User Pgm

User programming enable/disable.

Put:

! ADR 0F P XX <00 or 01> CSM <CR>

Reply:

A <CR>

Get:

! ADR 0F G XX CSM <CR>

Reply:

A <00 or 01> CSM <CR>

where “XX” is the channel number minus 1, in hex. “00” =
disable, and “01” = enable.

10

Motion Enab

Motion detection on/off for a specified output channel.

Put:

! ADR 10 P XX <00, 01, or 02> CSM <CR>

Reply:

A <CR>

Get:

! ADR 10 G XX CSM <CR>

Reply:

A <00, 01, or 02> CSM <CR>

where “XX” is the channel number minus 1, in hex. “00” = L1 &
L2 off; “01” = L1 on; “02” = L2 on.

Configuration