Per channel enable, Program copy, Password (cont’d) – Electro Cam PS-6144 Series User Manual

Page 49: 21 programming

Advertising
background image

3-21 Programming

Password (Cont’d)

Clearing a Password

When programming operations are completed, enter a password value of “0,” then ENT
to clear the enable level.

If a keypad is left unattended with an active password, the access code will clear after
five minutes of keypad inactivity and the keypad will revert to the “Normal Display”
mode shown in Figure 21.

See Also

ENABLE CODES

Per Channel Enable

Menu Path

MAIN SCREEN

to CONFIG MENU

to PGM ENABLES

to PER CHN ENABLE

Purpose

This screen is used to enable Operator Level access to individual output channels. PER
CHN ENABLE is used in conjunction with the ENABLE OPTIONS screen to assign
Operator Level access to selected programming functions.

Screen

CHN: 12<
CHN ENABLE: ON

Channel number
Per channel enable: ON/OFF
(Toggle with SEL key)

Channel Select

Press the INC/DEC keys, or use the numeric keys and ENT.

Enable Toggle

Press the SEL key to toggle the enable ON or OFF.

See Also

ENABLE OPTIONS

Program Copy

Menu Path

MAIN SCREEN

to SETUP MENU

to PGM COPY

Purpose

Program Copy allows you to copy all of the channels and setpoints from one program to
another. It is often easier to copy an existing program and modify it, than to enter a new
program from scratch.

Screens

The Program Copy function consists of four screens:

Programming

Use the numeric keys and SEL to enter program numbers. During programming, the
cursor keys allow you to move between the Source and Destination screens to allow
you to change values before selecting EXECUTE.

SRC PROGRAM:---<

Program to be copied from

DST PROGRAM:---<

Destination to be copied to

DST PROGRAM: 6<

EXECUTE<

Move cursor to EXECUTE, then press SEL
to copy program

DST PROGRAM: 6

COMPLETE<

COMPLETE indicates program
successfully copied