Motion anding, Output enable anding, Group programming – Electro Cam PS-6144 Series User Manual

Page 96: Run time control, Registers (cont'd)

Advertising
background image

6-24 Communications

Motion ANDing

40332

Channel Index
Read/write
Values: 1 - Max Channel Number
Channel index for the Motion Enable Level Register.

40333

Motion Enable Level
Read/write
Values: 0 = Off, n = Motion Detection Level
Specifies the motion detection level used for a channel.

Output Enable ANDing

40334

Output Enable Index
Read/write
Values: 1 - Max Channel Number
Channel index for the Output Enable register.

40335

Output Enable
Read/write
Values: 0=Channel not ANDed, 1=Channel ANDed
Specifies whether a channel is ANDed with the Enable Input.

Group Programming

40336

Group Quantity
Read/write
Values: 1 - 6
Specifies the number of output groups.

40337

Group Index
Read/write
Values: 1 - 6
Group index for Channel Quantity and Group Mode Registers.

40338

Channel Quantity
Read/write
Values: 0 - n
Defines the number of channels in the output group specified by the Group Index Register.

40339

Group Mode
Read/write
Values: 0 - 5
Defines the operating mode for the output group specified by the Group Index Register. Note
that groups in mode '0' do not need (or have) an enable input.

Run Time Control

40340

Stop Control
Read/write
Values: 0 = Running, 1 = Stopped
When PLuS is STOPPED, changes written to registers do not update the checksum in
EEPROM memory. Changes are faster when unit is stopped, but you must read from the
Checksum Register when changes are complete to establish a valid checksum. Writing a '1'
value to this register will place the PLuS in STOPPED mode. Writing a '0' to this register will
restart the PLuS via a watchdog timer reset.

40341

EEPROM Checksum
Read only
Returns the current checksum of EEPROM memory. If computed checksum of EEPROM
memory does not match the current value (i.e. if changes were made while unit STOPPED),
a new value will be written to EEPROM memory.

Registers (Cont'd)

Advertising