Features in 291-08

25

Version 291-10
C613-10488-00 REV G

CR00010306

Install

3

If a user attempted to enter a filename with an invalid format, the resulting
error message did not correctly describe the format that should have been
used. Also, the router or switch returned an incorrect error message when
a user attempted to delete a non-existent release licence file.

These issues have been resolved.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00010315

BGP

3

Previously, it was possible to enter bad BGP peer IP addresses, such as
0.x.x.x, 127.x.x.x and 255.255.255.255.

This issue has been resolved.

Y

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00010465

Switching

3

The “?” help for the command show switch sock=con inst=value
showed a maximum value of 4294967295.

This issue has been resolved. Valid instance values are 0 and 1.

-

-

-

Y

Y

Y

Y

-

-

-

-

CR00010538

Firewall

3

When firewall events were recorded in the Notify queue (displayed in
output of the command show firewall event=notify), the IP address
shown would be the address of the very first packet that belonged to that
event flow. For example, if 64 host scan packets were required to trigger a
host scan event and the first packet had a target IP of 1.1.1.1 and the 64th
had an IP of 1.1.1.64, then the IP address recorded would be 1.1.1.1, even
though the event was not actually recorded until the 64th packet arrived.
Additionally, the source and destination ports in this display would always
show as 0.

These issues have been resolved.The IP addresses shown are now those of
the particular packet that triggered the event notification, and the source
and destination ports match the actual ports used by that packet.

Y

Y

Y

Y

Y

Y

-

-

-

-

Y

CR00010976

PPP

3

If the router or switch received an Echo-Request that did not comply with
RFC 1661, it processed and replied to the Echo-Request.

This issue has been resolved. Non-complying Echo-Requests are now
ignored.

Y

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR

Module

Level

Description

AR4

00

AR7

x5

AR7

x0S

Rap

ier i

Rap

ier w

AT

-8800

A

T-8

600

A

T-8

700

XL

x900

-48

A

T-

99

00

A

T-9

800

Advertising