Allied Telesis AT-WA1104G-10 User Manual

Page 52

Advertising
background image

Features in 291-05

52

Version 291-10
C613-10488-00 REV G

CR00016228

QoS

3

If a QoS policy uses the same classifier more than once, the router or switch now
displays a warning message. You should not use a classifier more than once in a
policy because the operation of such policies is unpredictable.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00016463

DHCPv6

3

For the command create dhcp6 range, DHCPv6 now checks that the specified
address or prefix range is valid for the specified type of range.

Valid options are:

address1-address2 (e.g. 3ffe:1:2:3:4:5::1-3ffe:1:2:3:4:6::ffff)

This is a range of addresses for address assignment (type=normal or
type=temporary).

address/prefixLen (e.g. 3ffe:1:2:3:4:5::/96)

This is a range of addresses for address assignment (type=normal or
type=temporary).

address/prefixLen-address/prefixLen (e.g. 3ffe:1:2::/48-3ffe:1:40::/48)

This is a range of prefixes for prefix assignment (type=pd).

Y

Y

Y

Y

Y

-

-

Y

Y

Y

CR00016799

Core

3

For revision M1 of AR770S routers, the low-end threshold for monitoring the 1.2
volt rail was too high. This caused power supply monitoring false alarms.

To check the router revision, use the command show system and check the
“Rev” entry underneath the time and date.

This issue has been resolved—the threshold is now correct.

-

-

Y

-

-

-

-

-

-

-

CR00017008

Core

3

Revisions M3-1and later of the AR745 router do not support Redundant Power
Supplies. Therefore, for these routers, RPS monitoring information has been
removed from output of the command show system, and it is no longer
possible to use the command set sys rpsmonitor.

-

Y

-

-

-

-

-

-

-

-