3.4 Fieldbus

Type

Address Map

94

(2) Input and Output Signal Assignment for each Axis

The I/O signals for each axis consists of 4 words for each I/O bit register.

Ɣ The control signals and status signals are ON/OFF signals in units of bit.

Ɣ For the target position and current position, 2-word (32-bit) binary data is available and

values from -999999 to +999999 (unit: 0.01mm) can be used. Negative numbers are to be

dealt with two’s complement.䎃

Ɣ For the indicated position number and complete position number, 1-word (16-bit) binary data

is available and values from 0 to 255 can be used.

PLC Output (m is PLC output top word address for each axis number)




Address m

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Target

Position

(Lower word)




Address m+1

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Target

Position

(Upper word)

(Note)If the target position is a negative value, it is indicated by a two’s complement.


Address m+2

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Specified

Position No.

PC128

PC64

PC32

PC16

P

C

8

P

C

4

P

C

2

P

C

1


Address m+3

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Control Signal

B

K

R

L

JO

G

+

JO

G

-

JV

E

L



JI

S

L

SON

R

E

S

S

TP

HOME

CSTR

Caution: Set the position data in the range of the soft stroke (0 to effective stroke length) of

the actuator.

Caution: Set the operational condition in advance with using a teaching tool such as PC

software in the position number to be used. Selecting a position number with no

setting conducted will generate the alarm code 0A2 “Position Data Error”.

1 word=16 bit