7.3 Servo Adjustment

The parameters are preset at the factory before shipment so that the actuator operates stably

within the rated (maximum) transportable weight.

However, the preset setting cannot always be the optimum load condition in the actual use. In

such cases, servo adjustment may be required.

This section describes the basic servo adjustment method.

No. Situation that requires

adjustment

How to Adjust

Takes time to finish

positioning

Positioning accuracy is

not appropriate

1

Shorter takt time is

desired

x

Set Parameter No.55 “Position command primary filter time

constant” to “0” if it is set.

x

Increase the value of Parameter No.7 “Servo gain number”. By

setting a larger value, the follow-up ability to the position

command becomes better. Set the value to any of 3 to 10

roughly or up to 15 at the maximum. If the value is too large, an

overshoot is caused easily and may cause noise or vibration.

If the value of Parameter No.7 “Servo gain number” is

increased, also adjust the Parameter No.31 “Speed loop

proportional gain” in increasing direction to ensure the stability

in the control system.

To increase the value of Parameter No.31 “Speed loop

proportional gain” by about 20% of the default. Prior to the

setting, adjust Parameter No.7 “Servo gain number”.

2 Vibration is generated at

acceleration/deceleration

x

The cause of the problem is excessive

“acceleration/deceleration setting” or vulnerable structure of the

unit on which the actuator is installed. If possible, reinforce the

unit itself, first.

x

Decrease the values of “acceleration/deceleration setting”.

x

Decrease the number of Parameter No.7 “Servo gain number”.

If the Parameter No.7 “Servo gain number” is too low, it takes

long time to finish the positioning.

Speed is uneven during

the movement

3

Speed accuracy is not

appropriate

x

Increase the value of Parameter No.31 “Speed loop proportional

gain”. By setting a larger value, the follow-up ability to the speed

command becomes better.

Setting too large value makes the mechanical components easy

to vibrate. As a reference for the setting, increase the value little

by little by 20% from the initial setting.



Caution: Rapid and excessive settings are dangerous. They may devices including the

actuator to be damaged and/or people to be injured. Take sufficient note on

the setting.

Record settings during servo adjustment so that prior settings can always be

recovered.

When a problem arises and the solution cannot be found, please contact IAI.