ontrol and functions of Input and output signals of Remote I/O Mode

173

[4] Zone signal and position zone signal (ZONE1, PZONE)

Output

PIO Signal

ZONE1

(Note1)

PZONE

(Note1)

Pattern 0

{

{

Pattern 1

u

{

Pattern 2

u

{

Pattern 4

{

{

Pattern 5

{

{

{

: Available, u: Unavailable

Note1: PZONE Signal can be changed to ZONE1 and ZONE2 Signals by the setting in

Parameter No.149.

1)

Zone output signal

ON

OFF

Zone signal output setting zone

2)

3)

4) 5)

2)

3)

1)

4)

5)

Position 1 input

Start signal

input

(moving start)

Zone signal

turned OFF at

leaving from

setup zone

Zone signal

output at entry

into setup

zone

Moving

comp.

Positioning

completion

signal output

Stop

status

Acceleration

Velocity

Time

Deceleration

This is a function enables to turn a signal on while the actuator is passing a certain position (in

the zone range) or during a stop, in which there are two types.

1) Zone signal (ZONE1) ·······················The output signal is turned ON at the position set by the

proper parameter.

2) Position zone signal (PZONE) ·········The output signal is turned ON at the position set in the

position table.

The feature can play a role as the sensor for judging whether the completion position is good or

not at completion of pressing, setting the continuous operation zone in pitch feed or interlocking

operations of other units in the setting zone.

(1) Zone signal (ZONE)

Set the zone range to the relevant parameter.

1) parameter No. 1 : “Zone Boarder 1 “+” Side”

2) parameter No. 2 : “Zone Boarder 1 “-” Side”

The zone signal ZONE is kept effective also during the emergency stop unless the memory of

the origin is lost due to alarm.