3.3 Setting of Position Data

74

10) Zone - [mm]

(Note)

·········· Set the coordinate value on the negative side at which position

zone output signal PZONE is turned ON.

Note: If set to Zone + < Zone -, PZONE Signal turns ON out of the ranges of Zone + and Zone -.

11) Acceleration/deceleration mode ········ Select a proper acceleration/deceleration pattern

depending on the load.

Set

value

Acceleration/Deceleration

Pattern

Operation

0

Trapezoid

Velocity

Time

1

S-shaped Motion

(Refer to Caution at

S-shaped Motion)

Velocity

Time

Set the S-motion rate with parameter No.56.

2

First-Order Delay Filter

(Refer to Caution at

First-order Delay Filter)

Velocity

Time

Set the delay time constant with parameter

No.55.

Caution at S-shaped Motion

1) Since it requires a speed change during the operation, even if having the position

command or direct command that S-shaped motion is set while the actuator is moving,

S-shaped motion control cannot be performed and will be the trapezoid control.

Make sure to make a command while the actuator is stopped.

2) S-shaped motion control is invalid in the index mode of the rotary actuator.

It will be the trapezoid control even if S-shaped acceleration/deceleration control is

indicated.

3) Do not use S-shaped acceleration/deceleration control if the setting of the acceleration

time or the deceleration time exceeds 2 seconds. It will be the trapezoid control.

4) Do not pause on the move during acceleration or deceleration. It will change the speed

(acceleration) and may cause a danger.

Caution at First-order Delay Filter:

1) Since it requires a speed change during the operation, even if having the position

command or direct command that first-order delay filter is set while the actuator is

moving, first-order delay filter control cannot be performed and will be the trapezoid

control.

Make sure to make a command while the actuator is stopped.

2) First-order delay filter control is invalid in the index mode of the rotary actuator.

It will be the trapezoid control even if first-order delay filter control is indicated