Alarm

Code

Alarm

Level

Alarm Name

Cause/Treatment

0EE

Absolute encoder error

detection 2

Cause

: This is the condition where the position information

can not be detected in the absolute encoder.

1) Voltage drop of absolute battery.

2) The encoder relay cable or supplied actuator

cable is disconnected or its connector is not

plugged in correctly.

Treatment : 1) Check the battery alarm output BALM and

replace the battery if it is ON (OFF for Remote

I/O Mode).

2) Check if any wire breakage on a connector and

the condition of wire connections.

Whichever action is taken under 1) or 2), an

absolute reset must be performed. If the cables are

normal, faulty encoder is suspected. Please contact

IAI.

0EF

Absolute encoder error

detection 3

Absolute encoder is not detecting the position information

properly. (ABS encoder overspeed error)

Cause

: This error occurs in such cases as the speed

exceeded the tracing acceleration speed limit in the

drop by the brake release at the power cutoff of the

absolute type vertical axis. (This condition should

not occur in normal conditions of use. Take

sufficient note on forced brake release.)

Treatment : If the error is occurred, it is necessary to absolute

reset.

0F0

Driver logic error

Cause

: Exceeded load, parameter (motor type)

mismatched, noise, malfunction of controller, etc.

Treatment : Please contact IAI.

0F4

Mismatched PCB

This controller uses a different print circuit board depending on

the motor capacity.

Mismatch of connected motor and the PCB is detected in the

startup check.

Cause

: The actuator may not match the controller. Check

the model.

Treatment : Should this error occur, please contact IAI.

0F5

Nonvolatile memory

write verify error

It is verified at the data writing process to the non-volatile

memory that the data inside the memory and the data to be

written are matched. There was a mismatch detected in this

process.

Cause

: Faulty nonvolatile memory.

Treatment : When the error is caused even when the power is

re-input, please contact IAI.

0F6

Nonvolatile memory

write timeout

There is no response in the specified time duration during the

data writing to the non-volatile memory.

Cause

: Faulty nonvolatile memory.

Treatment : When the error is caused even when the power is

re-input, please contact IAI.

0F8

Nonvolatile memory

data destroyed

Abnormal data was detected during the nonvolatile memory

check after starting.

Cause

: Faulty nonvolatile memory.

Treatment : When the error is caused even when the power is

re-input, please contact IAI.

0FA

Cold start

CPU error

The CPU operation is not normal.

Cause

: 1) Faulty CPU

2) Malfunction due to noise

Treatment : When the error is caused even when the power is

re-input, please contact IAI.