Control and functions of Input and output signals of Modes other than Remote I/O Mode

Power Supply and Cutof

f

158

(15) Brake release (BKRL) PLC Output Signal

Operation

Mode

Positioner 1

Simple Direct

Direct numeric

specification

Direct numeric

specification 2

Positioner 2

Positioner 3

{

: Equipped

× : Not equipped

{

{

{

{

{

{

The brake can be released while BKRL signal is turned ON. For an actuator equipped with a

brake, the brake can be controlled automatically with the ON/OFF of the servo, however, it may

require to release the brake in such cases as when installing to the system or conducting Direct

Teach

*1

, when the slider or rod needs to be moved manually with hand. This operation also can

be performed with the brake release switch on the controller front panel, or by supplying 24V to

the brake power terminal on the control power connector.

*1 Direct Teaching: It is an operation to move the slider or rod manually with hand to read the

coordinate to the position table.

Warning: (1) Release the brake with a special care. Doing so carelessly may cause

an injury or a malfunction of actuator, work piece or other devices due to

a drop of the slider or rod.

(2) Make sure to put the setting back to activate the brake after releasing it.

It is extremely dangerous to perform operation with the brake open.

Drop of the slider or rod may cause injury or malfunction of actuator

body, work piece or system.

(16) Push-motion specification (PUSH) PLC Output Signal

Operation

Mode

Positioner 1

Simple Direct

Direct numeric

specification

Direct numeric

specification 2

Positioner 2

Positioner 3

{

: Equipped

× : Not equipped

Ч

Ч

{

{

Ч

Ч

When the movement command signal is output after this signal is turned ON, the pressing

operation is performed.

When this signal is set to OFF, the normal positioning operation is performed.

After reaching the target position

(Note 1)

from the current position, the actuator moves at the

pressing speed for only the distance set in the positioning width.

The positioning complete signal (PEND) turns ON if the work piece hits and pressing is judged

as completed while in the pressing operation.

Note 1: The value is that input in the target position register.

Speed

Movement distance

Target position

Positioning width (Max. pressing level)

Position where the actuator is pushed against

the work and the pressing completion is judged

so the positioning completion signal is turned “ON”

Advertising