Modbus – IAI America ROBO Cylinder Series User Manual

Page 103

Advertising
background image

5. Modbus RTU

95

Modbus

5.3.14 Controller Status Signal Reading 4 <<STAT>>

(1) Function

This bit reads the internal operation status of the controller.

[Refer to 4.3.2 (15), “Data of system status register.”]

(2) Query format

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Start address [H]

2

9008

System status register

Number of registers [H]

2

0002

Reading addresses 9008

H

to

9009

H

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

8

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Internal status of controller

Number of data bytes [H]

1

04

Reading 2 registers = 4 bytes

Data [H]

4

System status

System status [Hex]

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

9