Modbus – IAI America ROBO Cylinder Series User Manual

Page 60

Advertising
background image

4. Communicationn

52

Modbus

4.3.4 Data of Modbus Status Registers

Reference page

Address

[HEX]

Area name

Description

Symbol

RTU

ASCII

0000 to 0CFF Reserved for

system

0100

EMG status

EMGS

0101

Safety speed enabled status

SFTY

0102

Controller ready status

PWR

0103

Servo ON status

SV

0104

Missed work part in push-motion operation

PSFL

0105

Major failure status

ALMH

0106

Minor failure status

ALML

0107

Absolute error status

ABER

0108

Brake forced-release status

BKRL

40

40

0109

Cannot be used

010A

Pause status

STP

010B

Home return status

HEND

010C

Position complete status

PEND

010D

Load cell calibration complete

CEND

010E

Load cell calibration status

CLBS

40

40

010F

Device status

register 1

(DSS1)

Cannot be used

(88)

(216)

0110

Cannot be used

0111

Cannot be used

0112

Load output judgment status

LOAD

0113

Torque level status

TRQS

0114

Teaching mode status

MODS

0115

Position-data load command status

TEAC

0116

Jog+ status

JOG+

0117

Jog- status

JOG-

0118

Position complete 7

PE7

0119

Position complete 6

PE6

011A

Position complete 5

PE5

011B

Position complete 4

PE4

011C

Position complete 3

PE3

011D

Position complete 2

PE2

011E

Position complete 1

PE1

011F

Device status

register 2

(DSS2)

Position complete 0

PE0

(90)

41

(218)

41

0120

Emergency stop status

EMGP

0121

Motor voltage low status

MPUV

0122

Operation mode status

RMDS

42

42

0123

Cannot be used

0124

Home return status

GHMS

0125

Push-motion operation in progress

PUSH

0126

Excitation detection status

PSNS

0127

PIO/Modbus switching status

PMSS

42

42

0128

Cannot be used

0129

Cannot be used

012A

Moving signal

MOVE

42

42

012B to 012F

Expansion

device status

register

(DSSE)

Cannot be used

(92)

(220)

Advertising