5. Modbus RTU

56

Modbus

5.1 Message Frames (Query and Response)

Start

Address

Function code

Data

CRC Check

End

Silent

interval

1 byte

1 byte

n byte

2 byte

Silent

interval

(1) Start

This field contains a silent interval (non communication time) of 3.5 characters or longer.

(1 character = 10 bits)

Example: In case of 9600 bps, (10 x 3.5) bits x 1/9600 bps = 3.65 ms

Note If the response timeout error occurs, change parameter No. 45, “Silent interval

multiplier” or No. 17, “Min. delay for activating local transmitter” using the IAI teaching

tool as required.

(2) Address

This field specifies the addresses of connected RC controllers (01

H

to 10

H

).

Address = axis number + 1

Caution: The address is not equal to the corresponding axis number: be careful when

making settings.

(3) Function

The table below summarizes the function codes and functions that can be used with RC

controllers.

Code

[Hex]

Name

Function

01

H

Read Coil Status

Read coils/DOs.

02

H

Read Input Status

Read input statuses/DIs.

03

H

Read Holding Registers

Read holding registers.

04

H

Read Input Registers

Read input registers.

05

H

Force Single Coil

Write one coil/DO.

06

H

Preset Single Register

Write holding register.

07

H

Read Exception Status

Read exception statuses.

0F

H

Force Multiple Coils

Write multiple coils/DOs at once.

10

H

Preset Multiple Registers

Write multiple holding registers at once.

11

H

Report Slave ID

Query a slave’s ID.

17

H

Read / Write Registers

Read/write registers.

Note This manual explains about

mark function codes.

(Reference) The ROBONET gateway supports three types of function codes (03

H

, 06

H

and

10

H

).

[Please refer to the separate ROBONET Operation Manual.]