Modbus – IAI America ROBO Cylinder Series User Manual

Page 58

Advertising
background image

4. Communicationn

50

Modbus

(19) Data of expansion system status register (Address = 9015

H

) (SSSE)

Bit Symbol

Name

Function

15

-

Cannot be used

14

-

Cannot be used

13

-

Cannot be used

12

-

Cannot be used

11

ALMC Cold start level alarm

0: Normal

1: Cold level start alarm in occurrence

It becomes 1 when the cold start level alarm is being occurred. It

is necessary to cancel the cause of the alarm issuance and reboot

the power in order to resume the operation.

10

Cannot be used

9

Cannot be used

8

RTC

RTC (calendar) function

use

0:RTC (calendar) function not in use

1: RTC (calendar) function use

* Corresponding Model: ERC3, PCON-CA/CFA

7

Cannot be used

6

Cannot be used

5

Cannot be used

4

Cannot be used

3

Cannot be used

2

Cannot be used

1

Cannot be used

0

Cannot be used