Modbus – IAI America ROBO Cylinder Series User Manual

Page 31

Advertising
background image

3. Specifications

23

Modbus

3.3 Communication Connector Pin Assignment of PLC and PC

(Reference)

Fig. 3.6

In case of PLC made by Mitsubishi:

QJ71C24 RS232C

D-sub 9-pin connector (male: cable side)

One end of the

shielded cable shall

be connected to a

connector housing

or grounded.

In case of PLC made by Omron:

CJ1W-SCB or SCU RS232C

D-sub 9-pin connector (male: cable side)

In case of PLC made by Keyence:

KV-L20R RS232C

D-sub 9-pin connector (female: cable side)

PC: RS232C

D-sub 9-pin connector (female: cable side)

PC

To use flow control, connect RS

and CS as well as DR and ER.

Connect the shielded cable

to the connector housing

In case of PLC made by Omron:

CJ1W-SCB or SCU RS485

D-sub 9-pin connector (male: cable side)

In case of PLC made by Mitsubishi:

QJ71C24 RS485

Terminal block

(Set the toggle switch

to a two-wire system)

Transmission data- (SDA)

Transmission data+ (SDB)

Reception data- (RDA)

Reception data+ (RDB)

Transmission data-
Transmission data+

One end of the

shielded cable shall

be connected to a

connector housing

or grounded.

Wire cables based on the printed signal

names on the communication unit panel.

Transmission data+

Transmission data-

Reception data+

Reception data-

Transmission data-
Transmission data+

One end of the

shielded cable shall

be connected to a

connector housing

or grounded.

Transmission data-
Transmission data+

One end of the

shielded cable shall

be connected to a

connector housing

or grounded.

In case of PLC made by Keyence:

KV-L20R RS485

Terminal block

1: SG
2: Reception data- (RDA)
3: Transmission data- (SDA)
4: Reception data+ (RDB)
5: Transmission data+ (SDB)

(Set the toggle switch on the 485 (2) side)

[* Please refer to operation manual of each manufacturer for detailed explanations.]