Chapter 8: Recording Options
PETracer EML User Manual
106
LeCroy Corporation
Misc
Allows you to specify the following parameters for recording and uploading traffic:
•
Beep When Trigger Occurs: Causes the Analyzer to beep when a trigger event is
detected.
•
Save External Interface Signals: If selected, causes the Analyzer to save signals
from a Breakout Board as fields in the CATC Trace.
•
Preserve TC to VC mapping across the channels: Causes the Analyzer to use
whatever TC to VC mapping it established in the last recording.
•
Default TC to VC mapping button: Lets users manually configure the default
mapping.