Step 1 Click

and select one or more events from the menu.

Selecting an event automatically places it in the Available Events area.
This area serves as a parking lot where you can place event buttons
without them having any effect on the Analyzer.

Step 2 Drag the selected events from the Available Events area into one of

either the Global State cell or the Sequence cell (see “Global State vs.
Sequences” on page 111)
:

Global State Cell: If you want the Analyzer to always search for the event, place
it in the cell marked Global State.

Sequence Cell: To create an event sequence, place two or more events in the
faintly marked cell that reads Drag an event here to create a sequence. At this
point, the selected events have no effect because an action has not been
assigned.

Step 3 To select a sub-set of your selected event, right-click it and choose

Properties. A Properties dialog box opens that presents additional
options. For example, if you open the Properties dialog for Errors, you
can set the specific types of errors the Analyzer should look for.