Teledyne LeCroy Summit Z3-16 PCI Express Multi-lane Exerciser User Manual User Manual
Page 24
Teledyne LeCroy
Setting Up the Summit Z3‐16 Exerciser using a USB Connection
24
Summit Z3‐16 PCI Express Multi‐Lane Exerciser User Manual
The PETracer program opens.
Figure 3.4: Teledyne LeCroy PETracer PCI Express Protocol Analyzer
Note:
The software may be used with or without the Exerciser or Analyzer. When used
without an Exerciser or Analyzer attached to the computer, the program functions
as a CATC Trace Viewer to view and analyze captured traffic.
3.2
Setting Up the Summit Z3-16 Exerciser using a USB Connection
To connect the Exerciser using Ethernet (see
“Setting Up the Summit Z3‐16 Exerciser
using an Ethernet Connection” on page 25
).
To set up the Exerciser using a USB connection:
1. Connect the Exerciser to a 100‐volt to 240‐volt, 50 Hz to 60 Hz, 120 W power outlet
using the provided AC power adapter, or to the DC power connector if using the PCI
Express Test Platform.
2. Plug the Exerciser into either the host machine or the PCI Express Test Platform
16x2.5GT/s / 16x5.0GT/s / 16x8.0GT/s.
Note:
The Exerciser is capable of supporting supply voltages between 100 volts and 240
volts, 50 Hz or 60 Hz, thus supporting all known supply voltages around the world.