Mounting, Tabletop placement, Rack mounting – Extron Electronics SSP 7.1 User Guide User Manual

Page 103: Ul guidelines for rack mounting, Tabletop placement rack mounting

Advertising
background image

Mounting

This section outlines the various mounting options available for the SSP 7.1.

Tabletop Placement
Rack Mounting
Under-desk Mounting

Tabletop Placement

Attach the four provided rubber feet to the bottom of the unit and place it in any
convenient location.

Rack Mounting

UL Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation
of these products in a rack:

1.

Elevated operating ambient temperature — If the unit is installed in a closed or multi-
unit rack assembly, the operating ambient temperature of the rack environment may
be greater than room ambient temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient temperature (Tma: +122 °F,
+50 °C) specified by Extron.

2.

Reduced air flow — Install the equipment in the rack so that the equipment gets
adequate air flow for safe operation.

3.

Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.

4.

Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of the equipment nameplate ratings should be used when
addressing this concern.

5.

Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as the use of power strips).

SSP 7.1 • Mounting

97

Advertising