Symbols used in this manual – Extron Electronics SSP 7.1 User Guide User Manual

Page 85

Advertising
background image

Symbols Used in this Manual

When programming in the field, certain characters are most conveniently represented by
their hexadecimal rather than their ASCII values. The table below shows the hexadecimal
equivalent of each ASCII character:

ASCII to HEX Conversion Table

Space

.

Table 3.

ASCII to HEX Conversion Table

]

— carriage return with line feed

}

— carriage return (no line feed)

• —

space character

E

— Escape key

The

X/

values defined in this section are the variables used in the fields of the

command

response table

.

X!

— Audio Inputs (1-5)

1 and 2 = Digital audio, optical input

3 and 4 = Digital audio, coaxial input

5 = Analog input

X@

— Audio Outputs (1-8)

1 = Left Front

2 = Center

3 = Right Front

4 = Left Surround

5 = Right Surround

6 = Left Back

7 = Right Back

8 = Subwoofer

X#

— Status

0 = Off

1 = On

X$

— Volume Output Mode

0 = Fixed (volume no attenuation)

1 = Variable (default)

X%

— Bass and treble adjustment range in dB -10 to +10 dB in 1 dB increments (default

0 dB)

SSP 7.1 • SIS Commands

79