Add new unit -6, Figure 8-3. unit access table -6 – ADTRAN TSU 120e User Manual

Page 104

Advertising
background image

Chapter 8. Telnet/Terminal Menus

8-6

TSU 120 User Manual

61202129L1-1

Figure 8-3. Unit Access Table

Add New Unit

This adds a new device to the unit access table.

You must enter a device

U

NIT

ID

,

P

ASSCODE

,

U

NIT

T

YPE

, and

P

OLLED

F

LAG

.

Unit type can be

S

TANDARD

(which supports any TSU/TDU

Multiplexer and the ISU 512) or

TSU S

TANDALONE

(a single

port TSU with no option card slot).

You may select a passcode of

0

to

9999

for each device or

DEFAULT

. This results in the default passcode being used

(defined as 0022 in Figure 8-3).

Traps are normally sent from the unit in alarm to the TSU
120. For units in the Unit Access Table that are not chained
directly to the TSU 120 but are managed over Inband or the
FDL, traps are not automatically forwarded.

Polling must be enabled on the TSU 120 for these units in or-
der to receive Traps on the NMS. The TSU 120 can be con-
figured to poll selected units for traps by enabling the
polled option when adding or modifying a unit entry.

_____________________________Unit Access ____________________________

Unit ID

Passcode

Type

Polled

PollStatus

20

DEFAULT

Standard

No

3

0033

Standard

Yes

UP

6

0095

TSU Stand Alone

No

8

0022

Standard

Yes

UP

1) Add New Unit

2) Modify Unit

3) Delete Unit

4) Default Unit Passcode

0022

5) OK