Pattern result -6 – ADTRAN TSU 120e User Manual

Page 94

Advertising
background image

Chapter 7. Test Menu

7-6

TSU 120 User Manual

61202129L1-1

QRSS always runs at 64K/DS0.

Example

1. Select

QRSS

ALL

DS

0

S

by using the

Arrow Keys

.

2. Press

Enter

to record the selection. The TSU 120 starts to gen-

erate a QRSS test pattern and inserts the pattern into all
DS0s.

3. To end the test, select

N

ONE

.

PATTERN RESULT

Displays the results of the test currently active. Leaving and
returning to this menu item does not interrupt the test.

Pressing

2

injects errors into the test pattern. These errors are

detected by the device performing the pattern check.

QRSS

ALL

DS

0

S

Generates a QRSS test pattern and
inserts the pattern into all DS0s

QRSS

TST

DS

0

S

Inserts a QRSS pattern in those DS0s
mapped as TST in the currently active
map (A or B)

NONE

Terminates pattern generation

ES

The number of seconds with at least 1 bit error.

BES

The number of seconds with more than 1 bit error
and less than 320.

SES

The number of seconds with more than 320 bit
errors.

SYNC

Indicates if pattern sync is (yes) or is not (no) valid.
An asterisk (*) indicates if pattern sync has been lost
since the start of testing.

Advertising