ADTRAN TSU 120e User Manual

Page 80

Advertising
background image

Chapter 5. Configuration Menu

5-22

TSU 120 User Manual

61202129L1-1

RESTORE DELAY

Selects the time that elapses between the network
going out of alarm or data and the backup call
being taken down. If

NEVER

is selected, the user

must deactivate the backup mode.

Choices: 1 sec, 3 sec, 10 sec, 30 sec, 1 min, 5 min,
10 min, never

RETRY DELAY

Selects the time between redialing the external
DCE after failed dial attempts.

Choices: 10 sec, 30 sec, 1 min, 5 min, 10 min

NUM RETRIES

Selects the number of times the DBU will attempt
to redial if unable to connect.

Choices: None, unlimited, 3 times, 10 times.

BACKUP
TESTING

Selects the options for the automatic ISDN verifica-
tion feature of the Nx/DBU. Verification of the
backup circuit does not disrupt data on the T1.

B

ACKUP

T

EST

:

Selects the frequency of automatic backup circuit
verification by the DBU.
Choices: Manual, Hourly, Daily, Weekly

T

EST

H

OUR

:

Selects the hour of the day the Backup test will
occur.
Choices: 0-23

T

EST

D

AY

:

If Weekly Backup test is selected, selects which day
to perform the test.

Choices: Monday - Sunday

WKEND

LOCKOUT

If no backup is desired from midnight Friday to
midnight Sunday, set this selection to

ON

; other-

wise set to

OFF

.

Choices: On, Off

Menu Items

Description