Port test menu items for 0.1 nx56/64 -9, Dte loopbk -9 511 pattern -9 511 results -9 – ADTRAN TSU 120e User Manual

Page 97

Advertising
background image

Chapter 7. Test Menu

61202129L1-1

TSU 120 User Manual

7-9

Port Test Menu Items for 0.1 Nx56/64

0.1 Nx56/64 is the base Nx interface. It offers the following test
functions:

DTE LOOPBK

This initiates a loopback. The following options are available:

The TSU 120 checks the remote loopback activation by detecting
a proper response from the remote end. While waiting for the re-
sponse, the display shows Looping. If successful, the display
changes to

L

OOPED

-U

P

. If unsuccessful, the display shows

F

AILED

.

511 PATTERN

This activates the generation of the 511 test pattern. The follow-
ing options are available:

511 RESULTS

This displays the results of the 511 test indicated in the 511
option. The results are in the form of the number of errored sec-
onds. The error count can be cleared by pressing

Clear (Shift+9)

.

PRT

/

LCL

The Nx port activates both a Local
loopback (back toward the DTE) and a Port
loopback when either is invoked.

REMOTE

The remote loopback causes a V.54 code to
be sent to the far end. The Nx at the far end
activates a PORT/LCL loopback upon
detection of the V.54 code.

OFF

The loop is deactivated.

ON

The pattern check circuitry is enabled and a
test started. The test is ended by selecting

OFF

.

OFF

The pattern generation and check is
disabled.

Advertising