Appendix A. Understanding SNMP

61202052L1-1

TSU 120 User Manual

A-5

SNMP MIB BROWSER CONFIGURATION

The following steps, shown in Table A-1 are required to config-
ure Network Manager MIB variable access through the TSU
120:

Table A-1. How to Configure Network Manager MIB

Step

Action

1

Load the desired product MIBs on the network management station.
If, for example, the administrator is managing TSU 120 and ISU 512
devices, load

TSU 120.MIB, ISU512.MIB

, and

RFC1406.MIB

.

2

Create device entries in the NMS database for all units that are to be
managed through the TSU 120. The host unit should be configured as
the proxy agent for the external units. The IP address or host name
used for the proxy designation is that of the TSU 120.

3

Set community names in the device’s entries for external units to the
TSU 120 community name with the device Unit ID appended as
defined in the previous section TSU 120 SNMP ACCESS on page A-3.

4

Set the device timeout for all device entries in the NMS device data-
base to five seconds, including the host unit.