Chapter 7. Test Menu

7-4

TSU 120 User Manual

61202129L1-1

Figure 7-2. Network Loopback Tests

LOCAL LOOPBCK

There are three available choices for setting the local loopback:

Using the arrow keys, select a setting and record it by pressing

Enter

. The unit returns the display of

1)

LOCAL

LOOPBCK

and

2)

REMOTE

LOOPBCK

REMOTE LOOPBK

This activates the same loopbacks as Local Loopback but at the
far end. It uses either the inband loop-up code as specified by
ANSI T1.403 for line loopback (ATT In-Band LLB), or the FDL
as specified in ANSI T1.403 for payload and line loopback
codes. The following options are available:

LINE

ON

Activates the line loopback

PAYLOAD

ON

Activates the payload loopback

NO

LOOPBACK

Deactivates the loopback

ATT

IN

-

BAND

LLB

Activates the line loopback using
inband code

ANSI

FDL

PLB

Initiates the transmission of an FDL
payload loopup code toward the far
end

ANSI

FDL

LLB

Initiates the transmission of an FDL
line loopup code toward the far end

TSU 120

DS1

NI CSU

Payload Loopback

Line Loopback

Secondary