Dbu configuration menu items (tsu 120e only) -21 – ADTRAN TSU 120e User Manual

Page 79

Advertising
background image

Chapter 5. Configuration Menu

61202129L1-1

TSU 120 User Manual

5-21

DBU Configuration Menu Items (TSU 120e only)

Menu Items

Description

BACKUP MODE

In a backup condition, both ends of the circuit must
detect backup conditions before backup is acti-
vated. One DBU is set to

ORIGINATE

and the other to

ANSWER

.

Upon a network failure, only the Origi-

nate DBU initiates backup by dialing the Answer
end. Once called, the

Answer DBU

goes into backup

mode only if a backup condition is detected. This is
ideal for controlling where calls originate.

Choices: Disable, Originate, Answer

BACKUP ON

Selects the conditions that cause the Nx/DBU to
initiate Backup.

NET

FAIL

:

Backup occurs on

RED

ALARM

,

YELLOW

ALARM

,

BLUE

ALARM

, and

LOS

.

NET

/

DATA

FAIL

:

Backup occurs on the same conditions as

NET

FAIL

,

plus loss of data transitions on the data the Nx56/
64 receives from the network.

PATTRN VERIFY

Selects whether or not the DBU will use its pattern
generator and receiver to authenticate backup
attempts. When the local and remote units are both
Nx/DBUs, set to

ENABLE

; otherwise set to

DISABLE

.

Choices: Enable, Disable

BACKUP DELAY

Selects the time allowed to elapse between the net-
work going into alarm or no data transmissions
and the backup beginning.

Choices: 1 sec, 3 sec, 10 sec, 30 sec, 1 min, 5 min,
10 min