Ul/c-ul/csa application notes, Ce marking notes – Proface FP3900 - 19 Flat Panel" User Manual

Page 10

Advertising
background image

UL/c-UL/CSA Application Notes/CE Marking Notes

FP-2500/FP-2600 Series User Manual

9

UL/c-UL/CSA Application Notes

The FP2500-T42-24V/FP2600-T42-24V units are UL/c-UL listed products (UL File No.
E182139).
The FP conforms as a component to the following standards:

UL508 Industrial Control Equipment

UL1604 Electrical Equipment for use in Class 1 & 2 - Division 2, and Class III

Hazardous (classified) locations.

CAN/CSA-C22.2, No.1010-1 Measuement and Control Equipment Safety require-

ments for electrical equipment for measurement and
laboratory use.

FP2500-T42-24V (UL Registration Model No.:3280033-02)
FP2600-T42-24V (UL Registration Model No.:3280033-04)

<Cautions>

Be aware of the following items when building the FP into an end-use product:

• The FP unit's rear face is not approved as an enclosure. When building the FP unit into an end-

use product, be sure to use an enclosure that satisfies standards as the end-use product's overall
enclosure.

• The FP unit must be used indoors only.

• This unit should be installed in the front face of a metal panel.

• If the FP unit is installed so as to cool itself naturally, be sure to mount it in a vertical panel. Also,

be sure that the FP unit is installed at least 100 mm away from any adjacent structures or
machine parts. If these conditions are not met, the heat generated by the FP unit's internal
components may cause the unit to fail to meet UL standards.

UL1604 Conditions of Acceptability and Handling Cautions:

1. Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring

methods - Article 501- 4(b) of the National Electrical Code, NFPA 70 within the United
States, and in accordance with Section 18-152 of the Canadian Electrical Code for units
installed within Canada.

2. Suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Locations.
3. WARNING: Explosion hazard - substitution of components may impair suitability for Class I,

Division 2.

4. WARNING: Explosion hazard - when in hazardous locations, turn power OFF before replac-

ing or wiring modules.

5. WARNING: Explosion hazard - do not disconnect equipment unless power has been switched

OFF, or the area is known to be non-hazardous.

6. WARNING: Explosion hazard - do not connect/disconnect equipment unless area is known to

be nonhazardous.

The FP2500-T42-24V/FP2600-T42-24V are CE marked products that conform to EMC direc-
tives EN55011 Class A and EN61000-6-2.

For detailed CE marking information, please contact your local FP distributor.