FP-2500/FP-2600 Series User Manual

3-2

3.1 Installation

Creating a Panel Cut

Create the correct sized opening required to install the FP, using the installation dimen-
sions given.

Check that the installation panel or cabinet's surface is flat, in good

condition and has no jagged edges. Also, if desired, metal reinforcing
strips can be attached to the inside of the panel, near the Panel Cut, to
increase the panel’s strength.

• Panel thickness should be from 1.6mm [0.06in.] to 10.0mm [0.4in.].

Decide the panel’s thickness based on the level of panel strength re-
quired.

For easier maintenance, operation, and improved ventilation, be sure to
install the FP at least 100 mm [3.94 in.] away from adjacent structures
and other equipment.

2.6.4 FP Installation Dimensions

The installation gasket, installation fasteners and attachment screws are all required
when installing the FP.

Side View

Rear View

100

[3.94]

100

[3.94]

100

[3.94]

100

[3.94]

100

[3.94]

100

[3.94]

100

[3.94]

Panel

Panel Cut

Unit: mm [in.]

1.6mm [0.06in.] to 10.0mm [0.4in.]

> <