3 replacing ca3-blu12-01, 3 replacing ca3-blu12-01 -10 – Proface FP3900 - 19 Flat Panel" User Manual

Page 81

Advertising
background image

7.3 Backlight Replacement

FP-2500/FP-2600 Series User Manual

7-10

• Be sure not to pinch or cut any of the FP unit's internal wiring when

closing the case.

• If any of the attachment screws becomes misplaced, check to be sure

that they have not fallen inside the FP. If a screw has fallen inside the
FP, do not connect the unit’s power cord until it has been removed.

1) Turn the FP unit’s power OFF (i.e. dis-

connect the FP unit's power cord). Re-
move the three (3) I/F covers, and use
a Phillips screwdriver to remove the
case’s seven (7) rear attachment screws
and USB holder. Pivot the rear cover
open, starting from the top of the unit.

2) The cover is fastened at the bottom,

and hinges open.

3) Loosen the three (3) circuit board at-

tachment screws.

• Be sure not to break the rear

cover’s four (4) alignment
tabs when you open it.

• To prevent FP unit damage, be

sure the FP unit's rear cover
open/close direction is correct.

Since the attachment screws
are small, be sure not to lose
them or allow them to fall inside
the FP unit's case.

USB holder

Rear Attachment Screws

Attachment

Screws

7.3.3

Replacing CA3-BLU12-01

Advertising
This manual is related to the following products: