2 wiring, Connecting the power supply terminals – Proface FP3900 - 19 Flat Panel" User Manual

Page 44

Advertising
background image

FP-2500/FP-2600 Series User Manual

3-7

3.2 Wiring

1) Confirm that that the FP unit's Power Cord is unplugged from the power supply.
2) Use a screwdriver to remove the Power Input Terminal Block's clear plastic cover.
3) Unscrew the screws from the middle three (3) terminals, align the Ring Terminals and

reattach the screws.

4) Replace the Power Input Terminal Block's clear plastic cover.

• Confirm that the ring terminal wires are connected correctly.

• A torque of only 0.5 to 0.6 N•m is required to tighten an attachment screw.

L

AC Input Live Line

N

AC Input Neutral Line

FG

Grounding Terminal connected to
the FP chassis.

Power

Terminal

Block

Connecting the Power Supply Terminals

FP2500-T12/FP2600-T12

+

Positive electrode

-

Negative electrode

FG

Grounding Terminal connected to
the FP chassis.

Power

Terminal

Block

FP2500-T42-24V/FP2600-T42-24V

L N FG

L N FG

+ - FG