Channel setup jump, Bar graph, Control mode – Watlow ANAWIN 2 User Manual

Page 87: Percent of full scale, Previous screen

Advertising
background image

Viewing Channels

AnaWin User’s Guide 8-3

FIGURE 8-3

Gauge Display

Channel Setup Jump

Click the Channel Setup Jump button to jump to the channel parameters
screen for the selected channel.

Bar Graph

Each gauge’s bar graph is centered on the setpoint of the corresponding
loop. The setpoint is indicated by the triangular symbol and highlighted
in blue. The level of the colored bar indicates the process variable value
graphically. The color of the bar indicates the value of the process
variable relative to the process alarm and deviation settings.

Control Mode

The Control Mode field displays the control mode for each loop: Auto,
Manual, or Tune.

Percent of Full Scale

Use the Percent of Full Scale field to set the scale displayed on the
gauges. Larger percentages produce gauges with less detail or
resolution. Smaller percentages produce gauges with greater resolution.

Previous Screen

Click Previous Screen to return to the bar graph display.

Channel Setup
Jump

Bar Graph

Control
Mode

Percent of Full Scale

Previous
Screen