Data structures

3

BannerMessage

This structure is a high-level description for configuring the banner messages on Brocade Virtual
ADX.

boardID

This structure is the high-level description of the chassis board.

BpID

This structure is the high-level description of BP number.

TABLE 214

Attributes

Parameters

Type

Presence

Rules

Description

messageOftheDay

string

Mandatory

Maximum 2548 characters
is allowed. The string can be
from 1 – 2548 characters in
length.

This parameter specifies an ASCII
string message to be displayed on a
User’s terminal whenever a Telnet
CLI session is established.

connectionMessage string

Optional

Maximum 2548 characters
is allowed. The string can be
from 1 – 2548 characters in
length.

This parameter specifies an ASCII
string message to be displayed on
the Console when a user
establishes a Telnet session. This
message indicates where the user is
connecting from and displays a
configurable text message.

execMessage

string

Optional

Maximum 2548 characters
is allowed. The string can be
from 1 – 2548 characters in
length.

This parameter specifies an ASCII
string message to be displayed
when a user enters the Privileged
EXEC CLI level.

TABLE 215

Attributes

Name

Type

Required

Rules

Description

bootPromMac

string

Yes

The MAC address of the boot PROM.

model

string

Yes

The chassis model.

serialNum

string

Yes

The serial number of the chassis.

TABLE 216

Attributes

Name

Type

Required

Rules

Description

asmSlotNumber

unsignedInt

The chassis slot containing the module.

bpNumber

unsignedInt

The BP (numbered from 1 – 8 maximum).

Advertising