Using

the

Oscilloscope

23

Setting the

vertical position

1. Press the OSC OPTION key 

repeatedly until the following 
menu appears on the display. 

 – Time 
 – CH1 (or CH2) Zero 

OSC

OPTION

2. Use the Up/Down key to change the vertical 

position. 

Original

Setting the

vertical scale

1. Press the OSC OPTION key 

repeatedly until the following 
menu appears on the display. 

 – Time Base 
 – CH1 (or 2) Volts/Div 

OSC

OPTION

2. Use the Up/Down key to change the vertical 

scale. 

Original

Turning the

channel on/off

1. Press the MENU key and use the Up/Down 

keys to select the CH1(CH2) SETUP menu. 

2. Press F2 (Channel) repeatedly to turn on or off 

the channel. 

GDS-122 User Manual

24

MENU

CH1 SETUP

CH2 SETUP

ON

Channel

OFF

F2

Note that when using the Autoset function 
(page

127H

18), channels are automatically turned on or 

off. 

Selecting the

coupling mode

1. Press the MENU key and use the Up/Down 

keys to select the CH1(CH2) SETUP menu. 

2. Press F1 (Coupling) repeatedly to select DC, 

AC, or Ground coupling. 

MENU

CH1 SETUP

CH2 SETUP

AC

Coupling

DC

Ground

F1

The DC coupling shows both DC and AC 
signal. 
The AC coupling only shows the AC signal. 
The Ground coupling shows the ground line. 

DC

coupling

(center point is at the 
bottom due to DC 
offset) 

AC

coupling

(center point is at the 
middle since the DC 
offset is being 
removed) 

Inverting the

channel

1. Press the MENU key and use the Up/Down 

keys to select the CH1(CH2) SETUP menu. 

2. Press F4 (Inverted) to invert the waveform. 

Advertising