Turning ON/OFF the Power

The power switch to turn the power ON/OFF is located at the side of

the instrument. When you turn the power on after connecting the

probe/probe cable, a test screen with the Kanomax logo, model, and

the version of the firmware will be displayed for a few seconds

before it switches to the Normal Mode screen.









Battery Level Indicator

Check the “Battery Level Indicator” to
confirm the remaining battery level. The
battery consumption rate largely depends
on the measured air velocity. When the
batteries need to be replaced (or
recharged), the indicator will start blinking.

The screen may freeze if a high velocity is measured when the battery
level indicator is blinking.
The indicator changes as indicated below according to the remaining
battery level:


CONNECT PROBE

AND RESTART!

NO PROBE!

'12/04/12

a

15:40:23 ~


TC

C

1

0.87f
25.3e
64.1g

Power Switch

|: Power ON


O: Power OFF

Power ON

Connect the probe/probe

cable to the instrument

Normal Mode Screen (refer to P.18 for details)
1. Current date and time

4. Air temperature

*1

2. Time constant (P.20)

5. Humidity

*2

3. Air velocity

6. Battery level indicator

*

1Air temperature is available only on MODEL6531/6541/6542/6543/6533/6561.

*

2Humidity is available only on MODEL6531/6533.

Batteries must

be replaced.

Blinks

-

Locked Status -

When

is displayed, all functions of the

instrument will be locked. The current measurement
will be cancelled and data will NOT be saved. To release
the lock, turn off the power and replace the batteries.

Probe is not

connected

properly

Annual Calibration
Remainder

A year after

calibration

Press any key or
10 sec later…

When the probe is not connected
properly, the “NO PROBE!” warning will
be displayed as shown above. Turn the
power off, and check the connection of
the probe.

Normal

Flow

Last calibration

date

A year after the last calibration, a notice to
perform the annual calibration will be displayed
on the screen. The screen will switch to normal
measurement mode 10 seconds later or after any
key is pressed.

'12/04/12

a

15:40:23 ~


TC

C

1

0.87f
25.3e
64.1g



aaaa

CLIMOMASTER

aaaa

Version

a

4.00

aa

*

a

Now

a

Loading

a

!

a

*



oo

Calibration

o

Due

oooooo

Last

o

Done

Ooooo

2010/02/23

o

<Push

o

ANY

o

Key:Start>

1.

6.

2.

3.
4.
5.

Advertising