Page 1024: Spectrophotometer unit backing plate error, Spectrophotometer up-down unit cover open, Spectrophotometer unit cover open, Spectrophotometer sensor not mounted 4, Spectrophotometer unit backing plate error 4, Spectrophotometer unit cover open 4, Spectrophotometer unit eject guide not mounted 4

Advertising
background image

Spectrophotometer Unit not connected.

Spectrophotometer Unit not connected.

Cause

Corrective Action

The Spectrophotometer Unit is not installed correctly. Turn off the power and reinstall the Spectrophotometer Unit.

Spectrophotometer Sensor not mounted.

Spectrophotometer Sensor not mounted.

Cause

Corrective Action

The Spectrophotometer Sensor to be loaded into
the Spectrophotometer Carriage is not installed
correctly.

Turn off the power, and reinstall by pushing the two connectors all the way into the Spec-
trophotometer Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→P.965

Spectrophotometer Unit Calibration white tile error.

Spectrophotometer Unit Calibration white tile error.

Cause

Corrective Action

The White Calibration Tile is not
installed.

Install the White Calibration Tile.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→P.965

The White Calibration Tile is dirty.

Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")

→P.948

The performance of part of the
Spectrophotometer Sensor may
be impaired.

If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the
Spectrophotometer Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→P.965

Spectrophotometer Unit eject guide not mounted.

Spectrophotometer Unit eject guide not mounted.

Cause

Corrective Action

The Spectrophotometer Eject Guide is installed incorrectly,
such as being installed askew, or not pushed in all the way.

Make sure that the Spectrophotometer Eject Guide is loaded in the correct
position, push it in all the way, and press the OK button.

There is a foreign object on the Spectrophotometer Eject
Guide.

Remove the foreign object and press the OK button.

The performance of part of the Spectrophotometer Unit may be
impaired.

Turn off the printer, wait a while, and then turn it on again.
If the same message is displayed again, contact your Canon dealer for assis-
tance.

Spectrophotometer Unit Backing plate error.

Spectrophotometer Unit Backing plate error.

Cause

Corrective Action

The White/Black Backing Plate is not installed
correctly.

Remove and correctly attach the White/Black Backing Plate, and then press the OK button.
(See "Switching the White/Black Backing Plate (Optional) Color.")

→P.837

The White/Black Backing Plate is soiled.

Clean the White/Black Backing Plate and then press the OK button.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")

→P.948

Spectrophotometer up-down unit cover open.

Spectrophotometer up-down unit cover open.

Cause

Corrective Action

The Up-down Unit Cover of the Spectrophotometer Unit is open. Close the Up-down Unit Cover and press the OK button.

Spectrophotometer Unit cover open.

Spectrophotometer Unit cover open.

Cause

Corrective Action

The Spectrophotometer Unit Cover of the Spectrophotometer Unit is open. Close the Spectrophotometer Unit Cover and press the OK button.