Spectrophotometer read error.

Spectrophotometer read error.

Cause

Corrective Action

The Spectrophotometer Sensor to
be loaded into the Spectrophotome-
ter Carriage is not installed correct-
ly.

Turn off the power, and reinstall by pushing the two connectors all the way into the Spectrophotometer
Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→P.965

The color measurement pattern
was not printed correctly.

Check the color measurement pattern. If the printing is faint, clean the printhead and perform the opera-
tion again.
(See "Cleaning the Printhead.")

→P.928

The color measurement pattern is
out of alignment.

Pulling or lifting a printed color measurement pattern may cause the pattern to come out of alignment.
Perform the operation again taking care not to touch the color measurement pattern.

Execute Feed Priority to improve the printing position of the pattern for color measurement.
(See "Automatic Banding Adjustment.")

→P.804

If the same message is displayed again after performing the above operation, set Pattern Size to Large
on the Control Panel menu and perform the operation again.
(See "Menu Structure.")

→P.657

Alternately, it may be resolved by selecting Air Drying in Drying Method in the Color Measurement
Preferences
dialog box in the Color Calibration Management Console and selecting the Dry Separated
Chart
check box if it is off.
(See "Acquiring Color Measurement Data For Any Color Chart (Windows).")

→P.866

(See "Acquiring Color Measurement Data For Any Color Chart (Mac OS X).")

→P.902

The performance of part of the
Spectrophotometer Unit may be im-
paired.

Turn off the printer and wait a while before restoring power, and then perform the operation again.
If the same message is displayed again, contact your Canon dealer for assistance.

Clean calibration white tile because it may be dirty.

Clean calibration white tile because it may be dirty.

Cause

Corrective Action

The White Cali-
bration Tile may
be dirty.

Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")

→P.948

If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the Spectrophotometer
Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→P.965