Corrective action

Error

a.

Verify that the cable between the local array
and external array is connected properly.

b.

If the cable between the local array and
external array is connected properly,
disconnect and reconnect it. After
30 seconds, check the path status from
Command View XP or XP Remote Web
Console.

The LDEV's status cannot be determined. This occurs
when the LDEV does not exist. The reason for the error
could be:

The status appearing in
the Ex-Dev. Status column
is Normal, but the status
appearing in the LDEV
Status
is Unknown.

The LDEV was been created when the volume was
mapped.

The LDEV in the external LU was deleted by the
Volume Manager function.

If LDEV Status becomes Unknown by any reason other
than above, contact you HP account support
representative.

The following rows describe path status values
displayed in the Alternate Path list and corrective

The path status that
requires the action

actions for each status value. See

Notes on connecting

appears in the Alternate

external arrays

for notes on connection settings and

examples of recovery procedures, and then take the
corrective action.

Path list on the Path
Setting window (see

Setting alternate paths for
external LUs

).

Status: The path status is
unknown.

Unknown

Corrective action: The
path status cannot be
identified. Contact your
HP account support
representative.

Status: The external port
is blocked.

Blockade

Corrective action: The
external port is blocked
because of the
microprogram or
package replacement or
some other factor. Check
the local array's status. If
you cannot restore the
path, contact your
HP account support
representative.

Status: The external
array's configuration

External device setting
changed

changed. For example,
the path definition was

Troubleshooting External Storage XP

154