HP XP External Storage Software User Manual

Page 178

Advertising
background image

Examples of recovery
procedures

Path status

The volume may have been set as
a pair volume for data copy.

Illegal request

Check if the volume is set as a pair
volume for Business Copy XP,
Continuous Access XP, or another
copy program. If the volume is set
as a pair volume, the volume might
be protected because of the pair
status. If the volume is protected,
change the pair status or delete the
pair.

The volume may have been set as
a pair volume for data copy.

Response error

Check if the volume is set as a pair
volume for Business Copy XP,
Continuous Access XP, or another
copy program. If the volume is set
as a pair volume, the volume might
be protected because of the pair
status. If the volume is protected,
change the pair status or delete the
pair.

There is a problem with connection
to the external array. The following
are possible causes:

Cannot detect port

The fibre cable is not connected
properly.

The topology setting between
the external and target ports
does not match.

If the external array is
connected through switches, the
switches' settings might not be
appropriate.

Check if the fibre cable is
connected properly, and use LUN
Manager to set the Fibre Channel
port properly.

Hitachi SANtinel may have set LUN
security.
Check if LUN security is enabled.
If LUN security is enabled, disable
LUN security.